Parameter |
Unit |
Rating |
Full Load Input Current ±2A |
Amp |
65 |
Input voltage max Voc |
Vdc |
50 |
Maximum Solar array power |
Wp |
2000 |
Max current rating of SCC |
Adc |
50 |
Nominal Output voltage in inverter mode |
Vac |
220V ± 7V |
Nominal Output Frequency of Inverter |
Hz |
50 ± 1 HZ |
Output voltage regulation |
% |
180-220 |
Overload capacity |
Sec |
6 Retry |
Cooling Fan ON at temp |
OC |
60 (or >50% of Rated Load or >8A Charging or Solar I>15A) |
Cooling Fan Off at temp |
OC |
55 (or <40% of Rated Load or <5A Charging or Solar I<8A) |
Battery low voltage alarm per battery |
Vdc |
10.8 /10.5± 0.2 (11.5-default for LiFePo4 batt) |
Battery low voltage cut per battery |
Vdc |
10.5 /10.2± 0.2 (With 4 Retry) (11.0-default for LiFePo4 batt) |
Batter low cut recovery per battery through Solar |
Vdc |
12.7 ± 0.2 (or Mains or reset swich on front panel) |
|
|
14.4 ± 0.2 |
Max Battery charging voltage by grid per battery |
Vdc |
settable for Tub-14.4V/28.8V,FALT-14.2V/28.4V,SMF-14.2V/28.4,GEL-14.2V/28.4V, LiFePo4-14.0V/28.0V |
|
|
settable for Tub-13.8V/27.6V,FLAT-13.6V/27.2V,SMF-13.8V/27.6,GEL-13.8V/27.6V, LiFePo4-Maintain Boost With Trickle Charging |
Max Battery charging current by grid in Hi/Lo option |
Adc |
16/12 ±2A |
settable for Tub-12/16A,FLAT-10/14A, SMF-10/14A,Gel-10/16A, LiFePo4-12/16 |
|
|
14.4 ± 0.2 |
Max Battery charging voltage by Solar per battery |
Vdc |
settable for Tub-14.4V/28.8V,FALT-14.2V/28.4V,SMF-14.2V/28.4,GEL-14.2V/28.4V, LiFePo4-14.0V/28.0V |
|
|
settable for Tub-13.8V/27.6V,FLAT-13.6V/27.2V,SMF-13.8V/27.6,GEL-13.8V/27.6V, LiFePo4-Maintain Boost With Trickle Charging |
Battery High cut with Alarm per battery |
Vdc |
15.5±0.2 |
Battery High cut Recovery per battery |
Vdc |
14.5±0.2 |
Max Battery charging current by Solar |
Vdc |
20/30±2A ( Selectable from Setting) |
Max Charging current to battery by Solar+Grid |
Vdc |
20/30±2A ( Selectable from Setting) |
Grid low cut voltage (IT load/Normal load) |
Vdc |
180/100 ± 10 |
Grid low cut voltage recovery (IT load/Normal load) |
Vdc |
190/100 ± 10 |
Grid high cut voltage (IT load/Normal load) |
Vdc |
265/280 ± 10 |
Grid high cut voltage recovery (IT load/Normal load) |
Vdc |
255/270 ± 10 |
Grid charging Enable/Disable |
Yes |
Selection of UPS Load/Normal Load |
Yes |